Contact Info
+91-9810092279 info@ryaxtechnology.com
With the constantly rising of user bandwidth, operators also put forward higher demands for the port bandwidth and performance of aggregator. Raisecom RAX721-C series are next-generation carrier-class pre-aggregation and aggregation products that provide high performance, high reliability and high densities 1GE, 10GE, 25GE, 40GE and 100GE port types in a compact standard 1U enclosure, flexibly adapting to diversified operator’s network bandwidth requirements. They support rich Layer 2 and Layer 3 features, with advanced QoS features, customers' services at different levels can be flexibly and finely scheduled, and support various VPN services over IP/MPLS networks, to implement services isolation through network virtualization, greatly improved network capacity and utilization, and help customers build a powerful next-generation packet transport network.
Metro Ethernet Pre-aggregation and Aggregation
RAX721-C series working with Raisecom intelligent CPE RAX711 series can deliver high-capacity 1GE/10GE/40GE/100GE diversified metro ethernet pre-aggregation and aggregation. support complete standard CE2.0 E-Line, E-LAN, E-Tree and EAccess services, as well as VPWS, VPLS, H-VPLS, MS-PW, and BGP L3VPN services over MPLS, 6PE, 6VPE over MPLS, EVPN* over SR MPLS and EVPN* over SRv6* as a PE device. The service delivery can be very flexible and reliable. ZTP and hardwarebased CFM and SLA offer service providers an easier way to deploy and manage either devices or services. Various fault detection and protection mechanisms guarantee high availability and stability of services. The whole solution is simply and completely managed on brand new B/S structured RCView system.
Power Reliability | Dual hot-swappable power supplies with voltage/temperature monitoring |
Flexible Service Delivery | Standard CE2.0 service (E-Line, E-LAN, E-Tree, E-Access) delivery VPWS, VPLS, H-VPLS, MS-PW, L3VPN, 6PE/6VPE over MPLS EVPN over MPLS/SR on roadmap* Flexible traffic classification guarantees customer-defined service SLA |
Multicast | Full set of multicast routing and control protocols implemented for flexible multiple service access and aggregation |
Committed Network Resiliency | Protection mechanism including STP/RSTP/MSTP, switchport backup, IEEE802. lax Link Aggregation, MC-LAG, ITU-T G.8032 ERPS, Static/dynamic IP FRR, TE/LDP/VPN/EVPN* FRR, VRRP, MPLS PW redundancy, MPLS TE hot-standby* guarantee network resiliency in chain, star, mesh, dual-homing and ring topologies |
OAM & Hardware-based SLA | Hardware-based IEEE802. 1ag/ITU-TY.1731 end-to-end CFM (CCM interval 3.3ms), hardware-based ITU-T Y.1731 end- to-end SLA performance monitoring with test result showing on user-friendly GUI BFD helps customer achieve fast fault detection for dynamic IP services and MPLS services |
IPv4/v6 Dual-Stack | IPv6 for management and services 6PE/6VPE support helps customers plan their future network evolution |
Ethernet Service |
MAC addresses |
Jumbo frame up to 12288 Bytes |
|
4,094 VLANs, IEEE802.1Q, IEEE802.1P, IEEE802.1ad QinQ |
|
Layer 2 control protocol (L2CP) handling |
|
Super VLANs | |
Private VLAN (PVLAN) with primary, community and isolated type |
|
IP Service |
IPv4/v6 static routing |
RIPv1/v2/ng, OSPFv2/v3, ISISv4/v6 and BGP4/4+ |
|
SR-MPLS | |
PMTU IPv4/v6 | |
VRF Lite IPv4/v6 | |
DHCPv4/v6* server, client, relay, snooping |
MPLS Service |
MPLS L2VPN: VPWS, VPLS, H-VPLS, MS-PW |
MPLS L3VPN | |
MPLS EVPN* | |
6PE/6VPE | |
Inter-AS MPLS L2VPN Option A, C | |
Inter-AS MPLS L3VPN Option A, C | |
Static CR-LSP, LDP, CSPF, RSVP-TE, tunnel policy |
|
Multicast | IGMP v1, v2, v3 |
IGMP Snooping, MVR, VLAN copy, Proxy |
|
MLD v1, v2* | |
MLD Snooping* | |
PIM-SM and PIM-SSM IPv4/v6* | |
NG-MVPN | |
QoS |
Flexible Traffic classification base on MAC, IP, Port, VLAN, CoS, DSCP, etc. |
Traffic policing | |
Hierarchical CAR | |
H-QoS* | |
8 local priority, 8 queues per port | |
WRED | |
Traffic shaping per queue/port | |
SP/WRR/SP+WRR queue scheduling |
|
3-level H-QoS | |
Reliability | NSF |
IEEE802.1ax Link aggregation group, manual, LACP |
|
Muti-chassis LAG* | |
Switchport backup | |
STP, RSTP, MSTP, MRSTP | |
ITU-T G.8032 ERPS based on port or CFM, switchover time less than 50ms |
|
Loop detection | |
Ethernet fault propagation, MPLS PW fault propagation |
|
ULDP | |
IPv4/v6 ECMP | |
Static/dynamic IPv4/v6 FRR, TE/LDP/VPN FRR |
|
VRRP | |
MPLS PW redundancy, MPLS TE hot-standby* |
|
OAM | IEEE 802.3ah EFM-OAM |
IEEE 802.1ag/ITU-T Y.1731 CFM | |
ITU-T Y.1731 performance monitoring (LM, DM) for Ethernet and MPLS L2VPN |
MPLS Service |
MPLS L2VPN: VPWS, VPLS, H-VPLS, MS-PW |
MPLS L3VPN | |
MPLS EVPN* | |
6PE/6VPE | |
Inter-AS MPLS L2VPN Option A, C | |
Inter-AS MPLS L3VPN Option A, C | |
Static CR-LSP, LDP, CSPF, RSVP-TE, tunnel policy |
|
Multicast | IGMP v1, v2, v3 |
IGMP Snooping, MVR, VLAN copy, Proxy |
|
MLD v1, v2* | |
MLD Snooping* | |
PIM-SM and PIM-SSM IPv4/v6* | |
NG-MVPN | |
QoS |
Flexible Traffic classification base on MAC, IP, Port, VLAN, CoS, DSCP, etc. |
Traffic policing | |
Hierarchical CAR | |
H-QoS* | |
8 local priority, 8 queues per port | |
WRED | |
Traffic shaping per queue/port | |
SP/WRR/SP+WRR queue scheduling |
|
3-level H-QoS | |
Reliability | NSF |
IEEE802.1ax Link aggregation group, manual, LACP |
|
Muti-chassis LAG* | |
Switchport backup | |
STP, RSTP, MSTP, MRSTP | |
ITU-T G.8032 ERPS based on port or CFM, switchover time less than 50ms |
|
Loop detection | |
Ethernet fault propagation, MPLS PW fault propagation |
|
ULDP | |
IPv4/v6 ECMP | |
Static/dynamic IPv4/v6 FRR, TE/LDP/VPN FRR |
|
VRRP | |
MPLS PW redundancy, MPLS TE hot-standby* |
|
OAM | IEEE 802.3ah EFM-OAM |
IEEE 802.1ag/ITU-T Y.1731 CFM | |
ITU-T Y.1731 performance monitoring (LM, DM) for Ethernet and MPLS L2VPN |
|
TWAMP-Lite for Ethernet, IP, MPLS L3VPN, 6PE/6VPE* |
|
SAT: RFC2544, Y.1564 | |
Layer 2 loopback with MAC swap | |
MPLS ping and traceroute | |
VCCV ping and traceroute | |
BFD for interface, static routing, RIP, OSPF, ISIS, BGP, LDP, LSP, CR-LSP*, PW, MS-PW*, VRRP, FRR, PIM* |
|
Dying Gasp in case of power failure | |
Security | CPU CAR |
CPU anti-attack | |
DHCPv4/v6 Snooping | |
ARP filter, DAI | |
IPv4/v6* IPSG | |
DOT1X | |
ACL based on VLAN, CoS, MAC, EtherType, IP or user-define |
|
RADIUS, TACACS+ | |
Storm control (broadcast, multicast, DLF) |
|
Port-security MAC | |
Maintenance and Managemen |
Zero-Touch Provisioning |
SNMP v1/v2/v3 | |
Netconf, Telemetry* | |
CLI management by local CONSOLE, Telnet and SSHv2 |
|
KeepAlive, RMON, LLDP, Syslog | |
SFP digital diagnostic management (DDM) |
|
CPU, memory monitoring | |
Voltage and temperature monitoring | |
Synchronization | NTP, SNTP |
IEEE1588v2 TC* | |
Sync E |
Model | RAX721-C-2C24 | RAX721-C-6C48 |
Switching capacity | 640Gbps | 2.88Tbps |
Interface | 2x 100G/40G QSFP28/QSFP+ | 6x 100G/40G QSFP28/QSFP+ |
24 X 10G/1G/100M SFP+/SFP |
48 X 10G/1G SFP+/SFP | |
Power Supplies | 2 hot-swappable AC/DC power supplies provide 1+1 redundancy AC:220V, 100~240VAC DC: -48V, -36~-72V | 2 hot-swappable AC/DC power supplies provide 1+1 redundancy AC:220V, 100~240VAC DC: -48V, -36~-72V |
Power consumption | 73W | 347.8W |
Operating Temperature (Below altitude 1800m) | -5~55°C* | -10~55°C* |
Humidity | 10~90% non-condensing | 10~90% non-condensing |
Physical Specification | 1RU 444(W)mm X 360(D)mmx44(H)mm Weight: 4.47kg | 1RU 440(W)mm X 360(D)mmx44(H)mm Weight: 7.68kg |
Standards & Protocols | |
CE, UL, FCC compliance | |
EMC Class A | |
RoHS compliance | |
IEEE802.3, 802.3u, 802.3z, 802.3-2008 | |
IEEE802.1AB, 802.1D, 802.1Q, 802.1p, 802.1ad, 802.1ax, | |
IEEE802.3ah, 802.1ag, | |
IEEE1588v2 | |
ITU-T G.8031, G.8032, ITU-T Y.1731 | |
MEF CE2.0 Compliance, MEF6, 9, 10, 11, 13, 14, 16, 17, 20, 31, 36 | |
RFC826, 768, 792, 793, 1112, 1195, 1771, 1772, 1997, 2131, 2132, 2236, 2328, 2362, 2439, 2710, 2763, 2966, 3031, |
|
3032, 3034, 3035, 3036, 3037, 3046, 3065, 3101, 3107, 3137, 3209, 3277, 3315, 3376, 3473, 3567, 3618, 3623, 3630, |
|
4090, 4182, 4271, 4273, 4377, 4378, 4379, 4443, 4447, 4448, 4541, 4605, 4649, 4760, 4761, 4762, 4893, 5036, 5187, |
|
5286, 5357, 5462, 5575, 5659, 5883, 6511, 7130 |
Standards & Protocols | |
CE, UL, FCC compliance | |
EMC Class A | |
RoHS compliance | |
IEEE802.3, 802.3u, 802.3z, 802.3-2008 | |
IEEE802.1AB, 802.1D, 802.1Q, 802.1p, 802.1ad, 802.1ax, | |
IEEE802.3ah, 802.1ag, | |
IEEE1588v2 | |
ITU-T G.8031, G.8032, ITU-T Y.1731 | |
MEF CE2.0 Compliance, MEF6, 9, 10, 11, 13, 14, 16, 17, 20, 31, 36 | |
RFC826, 768, 792, 793, 1112, 1195, 1771, 1772, 1997, 2131, 2132, 2236, 2328, 2362, 2439, 2710, 2763, 2966, 3031, |
|
3032, 3034, 3035, 3036, 3037, 3046, 3065, 3101, 3107, 3137, 3209, 3277, 3315, 3376, 3473, 3567, 3618, 3623, 3630, |
|
4090, 4182, 4271, 4273, 4377, 4378, 4379, 4443, 4447, 4448, 4541, 4605, 4649, 4760, 4761, 4762, 4893, 5036, 5187, |
|
5286, 5357, 5462, 5575, 5659, 5883, 6511, 7130 | |
Part No. | Description |
RAX721-C-2C24 |
Standard 1U, 19” standalone IP/MPLS pre-aggregation device, 2 x 100G/40G QSFP28/QSFP+ for uplink, 24 x |
10G/1G/100M SFP+/SFP for downlink, CONSOLE and SNMP ports for management | |
-AC/D: dual hot-swappable AC power supply | |
-AC/S: single hot-swappable AC power supply and single FANS310 module | |
-DC/D: dual hot-swappable DC power supply | |
-DC/S: single hot-swappable DC power supply and single FANS310 module | |
-AC_DC: one hot-swappable AC power supply and one hot-swappable DC power supply |
|
RAX721-C-6C48 |
Standard 1U, 19” standalone IP/MPLS pre-aggregation device, 6 x 100G/40G QSFP28/QSFP+ for uplink, 48 x 10G/1G |
SFP+/SFP for downlink, 2FANs, CONSOLE and SNMP ports for management | |
-AC/D: dual hot-swappable AC power supply | |
-AC/S: single hot-swappable AC power supply | |
-DC/D: dual hot-swappable DC power supply | |
-DC/S: single hot-swappable DC power supply | |
-AC_DC: one hot-swappable AC power supply and one hot-swappable DC power supply |
Part No. | Description |
RPA1221-S-220S12 | AC power supply module for RAX721-C-2C24 |
RPD1241-48S12 | DC power supply module for RAX721-C-2C24 |
PAK550-220D12+12-CRPS | AC power supply module for RAX721-C-6C48 |
PDK550-48D12+12-CRPS | DC power supply module for RAX721-C-6C48 |
Part No. | Description |
FANS310 | Fan module for RAX721-C-2C24 |
FANS339 | Fan module for RAX721-C-6C48 |